Avalon Stoves 99200149 Stove User Manual


 
ZC Kit – Large Pellet Insert
(99200149)
Page 3 of 8 10/9/06 © Travis Industries, Inc.
Vent Termination Requirements (See the illustration below)
Must have an approved cap (to prevent water from entering) or a 45° downturn.
If the termination is located on a windy side of the house, an approved house shield is
recommended to prevent soot from building up on the side of the house.
Must not be located where it will become plugged by snow or other material.
Horizontal terminations must protrude 12" from the wall, vertical terminations require 24".
H
G
A
D
F
NOTE: Measure clearances to the nearest edge of the exhaust hood.
A
E
B
C
F
X
A Minimum 4' clearance below or beside any door or window that opens
B Minimum 1' clearance above any door or window that opens
C Minimum 2' clearance from any adjacent building
D Minimum 7' clearance above any grade when adjacent to public walkways
NOTE: Vent may not terminate in covered walkway or breezeway.
E Minimum 2' clearance above any grass, plants, or other combustible materials
F Minimum 3' clearance from any forced air intake of any other appliance
G Minimum 2' clearance below eaves or overhangs
H Minimum 1' clearance horizontally from combustible wall
X Must be a minimum of 2' above the roof