Ariston G.C.N.:47-116-67 (38 kW) Boiler User Manual


 
45
settings - adjustment - problem identi cation menus
menu
sub-menu
Parameter
Description value
default setting
524Compensation from 0 to 20 20 if setting = 0, the temperature
taken from the ambient sensor
does not a ect the calculation
of the setting. If setting = 20, the
temperature taken has maximum
in uence on the setting.
525Zone 2 heating MAXIMUM temperature
setting
from 35 to 85 °C 82 if parameter 520 = 1
from 20 to 45 °C 45 if parameter 520 = 0
526Zone 2 heating MINIMUM temperature
setting
from 35 to 85 °C 35 if parameter 520 = 1
from 20 to 45 °C 25 if parameter 520 = 0
5 3 DIAGNOSTICS
534Zone 2 heat request 0 = OFF
1 = ON
6 ZONE 3 PARAMETER
6 0
ZONE 3 TEMPERATURE SETTING
602Heating  xed temperature setting
“Heating  xed temp”
from 35 to 82 °C
(high temperature - para. 420 =1)
70 Activated only with temperature
control and  xed temperature (see
621)
from 20 to 45 °C
(high temperature - para. 420 =0)
20
6 2 ZONE 3 SETTING
620Heating appliance temperature value
setting
0 = from 20 to 45°C
(low temper ature)
1 = from 35 to 85°C
(high temperature)
1 select in the appliance type base
621Basic heating control type selection type
depending on the peripheral devices
connected
0 =  xed  ow temperature
1 = device On/O
2 = NOT PRESENT
3 = external sensor only
4 = NOT PRESENT
1 To activate heating control, press
the AUTO button. The display
lights up the AUTO symbol
622Slope from 0_2 to 0_8 (low temperature)
from 1_0 to 3_5 1_5 (high temperature)
- see graph on page 42
If the external sensor is used, the boiler calculates the most suitable heating  ow temperature taking the external temperature
and the type of appliance into account.
The type of curve must be chosen according to the type of appliance radiator and the heat losses present in the building.
623Parallel curve shift Zone 2 O set from - 7 to + 7 (low temperature) 0
from - 14 to + 14
(high temperature)
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the
calculated  ow temperature and therefore the ambient temperature.
By accessing this parameter or pressing the buttons 12 the curve can be shifted in a parallel manner as indicated in the  gure
shown below.
The value is indicated on the display:
- from -7 to +7
(low temperature)
- from -14 to +14
(high temperature)
Each step represents a  ow temperature increase/decrease of 1°C in relation to the
set-point value.
624Compensation from 0 to 20 20 if setting = 0, the temperature taken
from the ambient sensor does not
a ect the calculation of the setting.
If setting = 20, the temperature
taken has maximum in uence on
the setting.
625Zone 3 heating MAXIMUM temperature
setting
from 35 to 85 °C 82 if parameter 620 = 1
from 20 to 45 °C 45 if parameter 620 = 0
626Zone 3 heating MINIMUM temperature
setting
from 35 to 85 °C 35 if parameter 620 = 1
from 20 to 45 °C 25 if parameter 620 = 0