Ariston G.C.N.:47-116-66 (30 kW) Boiler User Manual


 
44
settings - adjustment - problem identi cation menus
menu
sub-menu
Parameter
Description value
default setting
423Parallel shift from - 7 to + 7 (low temperature) 0
from - 14 to + 14
(high temperature)
To adapt the thermal curve to the appliance requirements, it is possible to perform a
parallel shift of the curve in order to alter the calculated  ow temperature and therefore
the ambient temperature.
By accessing this parameter or pressing the buttons 12 the curve can be shifted in a parallel
manner as indicated in the  gure shown below.
The value is indicated on the display:
- from -7 to +7
(low temperature)
- from -14 to +14
(high temperature)
Each step represents a  ow temperature increase/decrease of 1°C in relation to the
set-point value.
424Compensation from 0 to 20 20
if setting = 0, the temperature taken from the ambient sensor does not a ect the calculation of the setting. If setting = 20,
the temperature taken has maximum in uence on the setting.
425Zone 1 heating MAXIMUM temperature
setting
from 35 to 85 °C 82 if parameter 420 = 1
from 20 to 45 °C 45 if parameter 420 = 0
426Zone 1 heating MINIMUM temperature
setting
from 35 to 85 °C 35 if parameter 420 = 1
from 20 to 45 °C 25 if parameter 420 = 0
4 3 DIAGNOSTICS
434Zone 1 heat request 0 = OFF
1 = ON
5 ZONE 2 PARAMETER
5 0 ZONE 2 TEMPERATURE SETTING
502Heating  xed temperature setting
“Heating  xed temp”
from 35 to 82 °C
(high temperature - para. 420 =1)
70 Activated only with temperature
control and  xed temperature (see
521)
from 20 to 45 °C
(high temperature - para. 420 =0)
20
5 2 ZONE 2 SETTING
520Heating appliance temperature value
setting
0 = from 20 to 45°C
(low temper ature)
1 = from 35 to 85°C
(high temperature)
1 select in the appliance type base
521Basic heating control type selection type
depending on the peripheral devices
connected
0 =  xed  ow temperature
1 = device On/O
2 = NOT PRESENT
3 = external sensor only
4 = NOT PRESENT
1 To activate heating control, press
the AUTO button. The display
lights up the AUTO symbol
522Slope from 0_2 to 0_8 (low temperature)
from 1_0 to 3_5 1_5 (high temperature)
- see graph on the previous page
If the external sensor is used, the boiler calculates the most suitable heating  ow temperature taking the external temperature
and the type of appliance into account.
The type of curve must be chosen according to the type of appliance radiator and the heat losses present in the building.
523Parallel curve shift Zone 2 O set from - 7 to + 7 (low temperature) 0
from - 14 to + 14
(high temperature)
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the
calculated  ow temperature and therefore the ambient temperature.
By accessing this parameter or pressing the buttons 12 the curve can be shifted in a parallel manner as indicated in the  gure
shown below.
The value is indicated on the display:
- from -7 to +7
(low temperature)
- from -14 to +14
(high temperature)
Each step represents a  ow temperature increase/decrease of 1°C in relation to the
set-point value.