Ariston 47-116-15 Boiler User Manual


 
Manufacturer: Merloni TermoSanitari SpA - Italy
Commercial subsidiary: MTS (GB) LIMITED
MTS Building
Hughenden Avenue
High Wycombe
Bucks HP13 5FT
Telephone: (01494) 755600
Fax: (01494) 459775
internet: http://www.mtsgb.ltd.uk
E-mail: info@mtsgb.ltd.uk
Technical Service Hot Line: (01494) 539579
23 99 84 1469 312 - Stampa: bieffe RECANATI
CE Certification
Heat Input max/min kW
Heat Output max/min kW
Efficiency of Nominal Heat Input %
Efficiency at 30% of Nominal Heat Input %
Heat Loss to the Casing (T=50°C) %
Flue Heat Loss with Burner Operating %
Flue Heat Loss with Burner Off %
Maximum Discharge of Fumes (G20) Kg/h
Residual Discharge Head mbar
Consumption at Nominal Capacity(G20) m
3
/h
Gas Consumption after 10 Minutes* m
3
(15°C, 1013 mbar) (G30-G31) Kg/h
Temp. of exhaust fumes at nominal capacity °C
CO
2
Content %
O
2
Content %
CO Content ppm
Minimum Ambient Temperature °C
Head Loss on Water Side (max) (T=20°C) mbar
Residual Head of System bar
Heating Temperature max/min °C
Domestic Hot Water Temperature max/min °C
D.H.W. Flow Rate T=35°C l/min
D.H.W. Flow Rate T=35°C gal/min
D.H.W. Minimum Flow Rate l/min
Pressure of Domestic Hot Water max/min bar
Expansion Vessel Capacity l
Expansion Vessel Pre-load Pressure bar
Maximum Water Content of System l
Maximum Heating Pressure bar
Nominal Pressure Natural Gas (G20) mbar
LPG (G30-G31) mbar
Electrical Supply V/Hz
Power Consumption W
Protection Grade of Electrical System IP
Internal Fuse Rating
Weight Kg
G.C. Number
27 MFFI
7. TECHNICAL INFORMATION
63AU4549
25.6/11.0
92.9
91.1
1.0
6.1
0.4
49.5
0.96
2.72
0.32/0.39
2.02/2.00
123
7.2
7.5
51.9
+5
200
0.25
82/42
56/36
9.7
2.2
2.6
8/0.2
6
1
130
3
20
30-37
230 / 50
140
X4D
FAST 2 AT
38
47-116-14
63AU4549
29.8/12.0
93.5
90.7
0.2
6.3
0.4
60
1.60
3.15
0.37
2.34/2.31
128.8
6.9
8.1
48
+5
200
0.25
82/42
56/36
11.4
2.6
2.6
8/0.2
6
1
130
3
20
30-37
230 / 50
155
X4D
FAST 2 AT
39
47-116-15
23 MFFI
*Calculated at 70% maximum output