7. Correct gas pressure is critical for the optimum
operation of this heater (see specifications on page 2). Gas
piping must be sized to provide the required pressure at
the maximum output of the heater, while all the other gas
appliances are in operation. Check with your local gas
supplier, and see the section on connecting the gas supply.
8. Should overheating occur or the gas supply fail to shut
off, turn off the gas supply at the manual gas shut off valve
on the gas line.
9. Do not use this appliance if any part has been
underwater. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the
control system and any gas control which has been
underwater.
PROPER LOCATION FOR INSTALLING
YOUR HEATER
Carefully select the location of your new heater. For your
safety and for proper heater operation, you must provide an
abundant supply of combustion air and a proper venting
installation.
The heater may still operate even when improperly vented.
It will, however, be less efficient and could eventually damage
the heater. It could even result in human sickness or death
due to oxygen deprivation and carbon monoxide poisoning.
Follow the guidelines below:
1. Place your heater as close to a vent or chimney as
possible.
2. National building codes require that you do not install
this appliance in bathrooms, bedrooms, unvented closet or
any occupied rooms normally kept closed.
3. Simultaneous operation of other appliances such as
exhaust fans, ventilation systems clothes dryers, fireplaces
or wood stoves could create a vacuum effect in your home
which could cause dangerous combustion by-products to
spill back into your home rather than venting to the outside
through the flue. Confirm that your Aquastar is venting
properly when all these other appliances are running. See
section on venting.
Do not obstruct the flow of combustion and ventilation
air to the appliance. If installed near a clothes dryer it is
very important that the dryer be properly vented. Failure to
properly vent a dryer could result in a gradual accumulation
of lint on the water heater fin coils and burners, leading to a
dangerous condition of vent blockage and poor unsafe
combustion.
4. Your hot water lines should be kept short to save energy.
It is always best to have hot water lines insulated.
This product is not approved for manufactured homes
(mobile home), recreational vehicles (RV) or boats.
Reference ANSI Z21.10.3.
This product is neither designed or approved for
outside installations.
WARNING: The water in this water heater is cold
and always remains cold except for the times that hot
water is being used DO NOT INSTALL IN AN AREA
WHERE IT COULD FREEZE.
This heater is neither designed for nor approved for
outside installation.
Drain the heater entirely if freezing temperatures are
anticipated in area where heater is installed by
disconnecting both the inlet and outlet elbow connections
at the rear of heater. Additionally remove the drain plug
under the water valve. See Fig 0.
WARNING: Flammable materials, gasoline,
pressurized containers, or any other items or articles
that are potentially fire hazards must NOT be placed
on or adjacent to the heater. The appliance area must
be kept free of all combustible materials, gasoline
and other flammable vapors and liquids.
COMBUSTION AIR REQUIREMENTS
The AquaStar water heater holds cold water in its copper
heat exchanger and brass water valve when not in use.
Because of this, any cold air that comes in through the
unit’s vent pipe is capable of freezing these components.
This Installation Manual specifies the minimum vertical vent
pipe and the amount of combustion air required for this
unit. The vent pipe must not be restricted and its 6 foot
minimum height (provided there are no elbows) must
terminate 2 feet above any obstruction within a 10 foot
radius.
When all requirements are followed, the unit will operate
properly and safely. However, there may still be a risk of
freezing due to negative draft if all the combustion appliances
in the area are not being supplied with a sufficient amount
of make-up air. A wood stove or furnace can rob the make-
up air in the AquaStar’s vent pipe, leaving the cold infiltrating
air capable of freezing the cold water in the AquaStar heat
exchanger. More make up air is the solution. Follow the
instructions on venting and checking adequacy of make up
air. A HVAC specialist should be used to design solutions
for providing more make-up air if necessary.
Observe the following instructions concerning combustion
air.
Appliances located in unconfined spaces:
a) An unconfined space is one whose volume is greater
than 50 cubic feet per 1000 Btu per hour of the combined
rating of all appliances installed in the space. That would
be 5850 cubic feet for the AquaStar 125BL alone.
b) In unconfined spaces in buildings of conventional frame,
masonry, or metal construction, infiltration is normally
adequate to provide air for combustion, ventilation, and
Fig. 0 - Water heater drain plug