10
Fig. 7 - Pressure Relief Valve
Connecting the pressure relief valve (PRV)
A listed pressure relief valve supplied with the heater must
be installed at the time of installation. No valve is to be
placed between the PRV and the heater. No reducing
coupling or other restriction may be installed in the discharge
line.
The discharge line must be installed such that it allows
complete drainage of both the PRV and the line.
The location of the PRV must be readily accessible for
servicing or replacement., and be mounted as close to the
water heater as possible. See Fig 7.
To install the PRV, a suitable fitting connected to an
extension on a “T” fitting can be sweated to the hot water
line.
If control button(s) are jammed, close the gas supply and
call a qualified service technician. Attempted forceful repair
may result in a fire or explosion.
D. Do not use this appliance if any part has been under
water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING INSTRUCTIONS (as seen on front
cover of heater)
1. STOP! Read the safety information above on this plate.
2. The gas valve must be turned off by depressing the gas
valve off button ( ).
3. Wait five (5) minutes to clear out any gas. If you smell
gas, STOP! Follow “B” in the safety information above
on this plate. If you don’t smell gas, go to the next step.
4. The pilot burner is located behind the peephole in the
front center of the jacket directly below this instruction
plate.
5. Depress PILOT button ( ) and light pilot by pushing
PILOT INGITER button ( ). This may have to be
repeated.
6. Observe the pilot flame through the peephole. The pilot
button ( ) should be held down at least 15 seconds
with pilot burning. When the pilot button is released the
pilot should continue to burn.
- If the gas valve button does not pop up when released,
stop and immediately call your service technician or gas
supplier.
- If pilot does not stay lit, repeat steps 1 through 6.
- If pilot will not stay lit after several tries, depress the OFF
button ( ), and call your service technician or gas
supplier.
7. When lit, depress the ON button ( ). The heater will
now fire when water is drawn at a rate greater than the
threshold flow rate.
NOTE: If main burner should fail to ignite, make sure
pilot is burning. If not, repeat lighting steps 1 through 6.
TO TURN OFF GAS TO APPLIANCE
Depress the OFF button ( ) and close the gas supply to
the heater.
INFORMATION ABOUT WATER TEMPERATURE
The AquaStar 125B LPL and 125B NGL water heaters
produce a 90°F temperature rise at 1.8 gallons per minute.
As the flow rate is increased above 1.8, gallons per minute,
the temperature will decrease.
MAINTENANCE AND SERVICE
(see maintenance table on back of manual)
Approximately once a year, the AquaStar should be checked
and cleaned. To remove the front cover, first remove the
incandescent particle tray, then unscrew the central screw
located at the bottom of the front cover. Pull main cover out
OPERATING INSTRUCTIONS
Before proceeding with the operation of the heater make
sure that the system is filled with water.
Open the cold water inlet supply to the heater fully.
Open a hot water faucet to permit the water to fill the heater
and the piping and to eliminate the air trapped in the system
Close the hot water faucet after the water flows freely and
all the air has escaped from the system. The water heater
is now ready to operate.
FOR YOUR SAFETY READ BEFORE
LIGHTING THE PILOT
Warning: If you do not follow these instructions
exactly, a fire or explosion may result causing property
damage, personal injury or loss of life
A. This appliance has a piezo-igniter for lighting the pilot
burner. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone
in your building
- Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
buttons. Never use tools. If a button will not push in, check
to make sure the buttons are being pushed in the proper
sequence. Follow these instructions exactly.