SEASONAL USE & SHUT DOWN
DURING THE SWIM SEASON
o During the swim season, even if the pool or spa is not in use, allow water to flow
through the heater.
o This eliminates the need to reposition valves when you do wish to heat your pool
or spa.
FREEZE PROTECTION / EXTENDED SHUT DOWNS
o In areas where freezing conditions are a rare occurrence, allow the filtration
system to run continually through the freeze period. Typically, during light
freeze conditions, circulating water will not freeze.
o In areas where freezing conditions are prevalent, please refer to winterizing
instructions following this section.
WINTERIZING
To Winterize a Heat Pump Equipped with an Internal Drain
(Per Figures 1 & 2)
1. Disconnect all electrical power to the heater; turn OFF circulating pump.
2. At the two (2) connection unions, disconnect the plumbing to the heater
(removal is counter-clockwise).
3. Remove the front plastic panel by removing the screws shown in Figure-1.
4. Locate the drain plug at base of the titanium condenser and remove (removal is
counter-clockwise). See Figure-2.
CAUTION
!
Failure to heed the following can result in
damage to equipment and/or property.
Failure to properly winterize unit may result in freeze damage to the heat
pump. Freeze damage is not covered under the unit warranty.
WARNING
!
Failure to heed the following may result in
permanent injury or death.
To avoid injury from rotating equipment (fan blade), disconnect electrical
power to heat pump before proceeding with winterizing process.