Aquacal 100 Heat Pump User Manual


 
37
SPECIFICATIONS
-Performance/Size/Weight-
-Water/Electrical Requirements-
* All A-Voltage 120 heaters with model numbers ending in “B”, MCA = 33
120 - Heating Only Models
120AHDE 120BHDE 120DHDT 120HHDT
BTU - 80%RH
Air ºF / Water ºF…80/80 109,000 109,000 95,000 95,000
COP 5.6 5.6 5.5 5.5
Voltage/Hz/Phase 208-230/60/1 208-230/60/3 380-415/50/3 200-240/50/1
Min. Circuit Ampacity 38 27 13 37
Max. Fuse or Breaker 60 45 20 60
Rec. Fuse or Breaker 40 30 15 40
Min-Max Water Flow (gpm)
20-70 20-70 20-70 20-70
Shipping weight (lbs) 323 323 323 323
Shipping Size (l x w x h) 40" X 36" X 44" 40" X 36" X 44"
40" X 36" X 44"
40" X 36" X 44"
Uncrated Weight (lbs) 296 296
296
296
Uncrated Size (l x w x h) 34” X 31” X 39” 34” X 31” X 39”
34” X 31” X 39”
34” X 31” X 39”
*
120 – Heat & Cool Models (Reversing)
120ARDE 120BRDE 120DRDT 120HRDT
BTU - 80%RH
Air ºF / Water ºF…80/80 103,000 103,000 92,000 92,000
COP 5.4 5.6 5.4 5.4
Voltage/Hz/Phase 208-230/60/1 208-230/60/3 380-415/50/3 200-240/50/1
Min. Circuit Ampacity 38 27 13 37
Max. Fuse or Breaker 60 45 20 60
Rec. Fuse or Breaker 40 30 15 40
Min-Max Water Flow (gpm)
20-70 20-70 20-70 20-70
Shipping weight (lbs) 330 330 330 330
Shipping Size (l x w x h) 40" X 36" X 44" 40" X 36" X 44"
40" X 36" X 44"
40" X 36" X 44"
Uncrated Weight (lbs) 303 303
303
303
Uncrated Size (l x w x h) 34” X 31” X 39” 34” X 31” X 39”
34” X 31” X 39”
34” X 31” X 39”
*