with ceramic ring. Caution: Do not grip impeller sleeve.
3. Reinstall the wear ring over the impeller hub in correct orientation.
Reinstalling the Suction Cover
1. Inspect the o-ring for damage. Replace if necessary.
2. Properly install the o-ring on the cover before mounting the cover to the volute.
3. Cover can be mounted to the volute in one orientation only. An ‘aligning’ feature is built-in with each part, to ensure
proper mounting. When properly aligned, the cover should slide in easily.
4. Secure the cover to the volute with screws. Tighten all screws alternately (crisscrossing the cover) to achieve
proper o-ring compression and cover seating.
5. Rotate the impeller by hand to make sure that it is rotating freely, without any interference.
Reconnecting the Pump Unit
1. Clean the seals, gaskets, or o-rings of the plumbing connectors. Replace if cracked, worn, or damaged.
2. Reconnect the plumbing lines to the pump. Hand tighten only.
3. Be sure that the pump unit is secured properly to the platform or base, if applicable. Tighten the bolts if necessary.
4. Reconnect the power supply. Be sure that all wires are properly and securely connected.
CAUTION: BEFORE TURNING THE POWER ON, BE SURE THAT: 1) THERE IS AN ADEQUATE AMOUNT OF WATER IN THE
SYSTEM
; 2) ALL VALVES ARE OPEN TO ALLOW WATER CIRCULATION; 3) ALL CONNECTORS AND FITTINGS ARE PROPERLY
ALIGNED AND SECURE.
FLO-MASTER
®
"TMCP" SERIES PUMPS LIMITED WARRANTY
Aqua-Flo, Inc.
Third year 60%
Fourth year 40%
Fifth year 20%
EXCLUSIONS
1. This warranty shall not apply to any failures
resulting from negligence, abuse, misuse, misapplication,
improper installation, alteration or modification, chemical
corrosion, or improper maintenance.
2. Any items manufactured by other companies
and used by AQUA-FLO in its products may carry
warranties by the original manufacturers.
3. AQUA-FLO is not liable for incidental or
consequential damages, loss of time, inconvenience,
incidental expenses, labor or material charges in
connection with removal or replacement of the
equipment.
AQUA-FLO is not responsible for any implied
warranties or representations by others and the foregoing
warranty is exclusive and in lieu of all warranties provided
herein.
Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and
you may also have other rights, which vary from state to
state.
WARRANTS TO:
____________________________________________
________________________________________________________________________________________________
the original retail purchaser only, that the
products they manufacture are free from defects in
material and/or workmanship for a period of five years
(pump seals warranty for 30 days) from date of purchase.
If within the first two years, any such products shall prove
defective, it shall be repaired or replaced at AQUA-FLO’S
option as follows:
The original retail purchaser shall first contact the
installing dealer, as soon as possible after discovery of
the defect, but in no event later that the expiration date of
this warranty. Or upon notification,
AQUA-FLO, INC.
Customer Service Department
P.O. Box 2526, Chino, CA 91708
will advise the consumer of the address to which
the defective item may be shipped, together with the
model number, serial number and date of purchase of
item claimed to be defective. The consumer must pay for
all shipping charges.
If within the years three through five any such
products shall prove defective, the original retail
purchaser shall be entitled to purchase replacement
equipment or components at the following percentage off
the current published list price: