INSTALLATION & OPERATING INSTRUCTIONS
GENERAL
Your AQUA-FLO pump has been quality built and engineered to give maximum
efficiency under normal water pumping conditions. Consult the manufacturer for
any other applications.
LOCATION OF PUMP
For best pump performance, locate the system as close to the water source as
possible. Provide adequate access around the pump for inspection and
maintenance. Place pump on a firm level surface. Pump need not be bolted
down unless required by local code.
PUMP CONNECTIONS
Suction line from pool (skimmer and main drain) must be connected to inlet at
hair and lint trap. Discharge line to pool (return lines) must be connected to
outlet at top of pump via filter. If pump is installed below water level of pool,
install valves on the inlet and outlet piping to permit removing of equipment
without draining the pool.
CAUTION
: During the pressure test procedure, this pump is under pressure.
DO NOT LOOSEN lock handles while pump is running or until all pressure is
released. Tighten lock handles securely by hand only. Raise pressure slowly.
Do not exceed 50 psi. Extreme care must be taken during pressure test. Failure
to follow these instructions explicitly can result in personal injury.
PRIMING PUMP
At initial start-up, pump must be primed by filling hair and lint trap with water. To
prime pump, remove cover from hair and lint trap: fill pump and suction trap with
water. Replace cover (make sure the o-ring is in place) and tighten lock handles.
Pump will now prime, with priming time depending upon lift and horizontal
distance of suction piping.
CAUTION
: Do not remove hair and lint strainer lid while pump is running or
under pressure! Lid is held in place by lock handles which can be removed or
tightened by hand. Basket must be kept clear of leaves and debris at all times.
REMOVING BASKET
1.) Turn off motor. 2.) Remove lid. 3.) Remove basket and empty debris. 4.)
Replace basket, fill with water, replace lid securely to prevent air from
entering and tighten. DO NOT USE TOOLS. 5.) Turn on motor. 6.) Open
air-relief valve on top of filter until steady stream of water comes out.
NOTE: If pump is installed below water level of pool, close return and suction
lines prior to opening hair and lint pot. Make sure to re-open valves prior to
operating.
DO NOT RUN PUMP DRY!
Always maintain proper water level in pool. If water level falls below skimmer
intake, pump will suck air. Pump is equipped with a maintenance-free, heavy-
duty mechanical seal. Damage will occur if pump runs dry, and warranty will be
voided.
TO PREVENT FREEZING
Drain liquid from pump through plug at bottom section of volute. It is
recommended to apply a good rust inhibitor into liquid end to prevent corrosion.
2