12 13
SETUP & TESTING
SYSTEM TEST MENU
The system test menu is used to test a system after installation. The outputs of the thermostat or humidistat can be
manually activated to test their function. The instructions below show how to enter the test mode and turn outputs
on and off.
Test Number Thermostat System Test
60 Heating equipment test
61 Cooling equipment test
62 Auxiliary equipment test (HP only)
63 Fan equipment test
The test number is displayed on the upper left, and the
output state is displayed in the message center.
Press
to turn on the output (01). For multi stage
output, press
again to turn on the 2nd stage (02).
Press
to turn off all the outputs (00).
Press [BACK] or [NEXT] to change to the next test
step.
When the last step is done, press [NEXT]. The
message “installer test complete“ will display.
All minimum on and off timers will be reset after
returning from system test mode.
Note: Second stage will only be displayed when the
thermostat is set to multi-stage mode.
TEST NUMBER MODEL
(SW1 SETTING)
FLASHES
IF 24VAC
IS NOT
PRESENT
STAGE
OUTPUT
STATE
HOW TO ENTER THE SYSTEM TEST MENU:
Press [MODE] to set system to off.
Press and hold [FAN] and [MODE] for three seconds
to enter system test mode. Note: Buttons will not be
shown in humidistat mode. Press in the same area that
the button would be displayed.
The screen of the first test step is displayed:
Test Number Humidistat System Test
70 Humidification equipment test
71 Dehumidification equipment test
SYSTEM TEST TABLES
SETUP & TESTING
Test 60: Heating Equipment Test
Button
Press
Equipment
Type
Stages
Heat
Type
W W2 Y Y2 G O B
1st UP
press
Heat Cool
Gas ON ON
Electric ON ON ON
Heat Pump ON ON ON
2nd UP
press
Heat Cool
1
2
Gas ON ON ON
Electric ON ON ON ON
Heat Pump
1
2 ON ON ON ON
Test 61: Cooling Equipment Test
Button
Press
Equipment
Type
Stages W W2 Y Y2 G O B
1st UP
press
Heat Cool ON ON ON
Heat Pump ON ON ON
2nd UP
press
Heat Cool
1
2 ON ON ON ON
Heat Pump
1
2 ON ON ON ON
Test 62: Auxiliary Equipment Test (HP only)
Button
Press
Equipment
Type
Heat
Type
W W2 Y Y2 G O B
1st UP
press
Heat Pump
Gas ON ON
Electric ON ON ON
2nd UP
press
Heat Pump
Gas ON ON ON
Electric ON ON ON ON
Test 63: Fan Equipment Test
Button
Press
W W2 Y Y2 G O B
1st UP
press
ON
Test 70: Humidifier Equipment Test
Button
Press
W W2 Y Y2 G O B
1st UP
press
ON ON ON
Test 71: Dehumidifier Equipment Test
Button
Press
W W2 Y Y2 G O B
1st UP
press
ON ON ON