WHOLE HOUSE / LOCALIZED CONVERTIBLE INSTALLATION AND OPERATION
In this configuration the dehumidifier will automatically switch between whole-house dehumidification when the HVAC
equipment is on, and localized dehumidification when the equipment is off. This installation is used to dehumidify a whole house
and a separate unconditioned space like an unfinished basement, or an area where circulation from that location throughout the
entire house is undesirable.
2 – 6508 Normally Closed Power Open Damper
2 – 6608 Normally Open Power Closed Damper
Duct Work
24 VAC Transformer (40 VA minimum)
Thermostat Wire
REQUIRED COMPONENTS OPTIONAL COMPONENTS
6506 Ventilation Damper
24 VAC Transformer (10 VA minimum) for Ventilation Damper
8052 Outdoor Temperature Sensor
Normally Closed Condensate Overflow Safety Switch
OPTIONAL
OUTDOOR AIR INTAKE
6“ MIN
RETURN
AIRFLOW
6“ MIN
AIR CLEANERCOOLING COIL
OPTIONAL
N.C. DAMPER
HVAC UNIT
1700
N.O. DAMPER
3‘ MIN
SUPPLY
AIRFLOW
N.O. DAMPER
N.C. DAMPER
N.C. DAMPER
RETURN FROM
UNCONDITIONED
SPACE
SUPPLY TO
UNCONDITIONED
SPACE
FIGURE 9 – DUCTING