7. Select and fit the correct orifices from the conversion kit, based on the gas
data table (3.4.3 "Gas data"). The orifice diameter is stamped on the orifice
itself, see (3).
8. Re-fit the burners back in their original position.
9. Re-fit the retaining strips.
10. If the radiation shield / condensation tray was loosened, re-fasten it.
Conversion of gas control
11. Check whether there is a burner pressure regulator (1) attached to the gas
control, or simply a blank plate (5).
Note
If the supply pressure for a gas category is the same as the burner pressure
(see the gas data table (3.4.3 "Gas data")) then the gas control must be fitted
with a blank plate with cork gasket. A burner pressure that deviates in
comparison to the supply pressure requires the use of a burner pressure
regulator with rubber gasket. Each conversion kit contains all the necessary
components.
12. If the blank plate or burner pressure regulator need to be replaced:
- Unscrew the connector (4) of the gas control.
- If necessary, remove the blank plate or burner pressure regulator (5)
or burner pressure regulator (1).
- If necessary, fit the blank plate or burner pressure regulator supplied
with the conversion kit.
- Fit the connector (4) of the gas control.