A.O. Smith 120 trough 500 Water Heater User Manual


 
BTR TANK TYPE HEATERS
SERVICE HANDBOOK
A.O. Smith Water Products Service Handbook
Irving, Texas ©2000 Training Department
25
GO TO PAGE 27 FOR DAMPER TESTS OF EFFIKAL EQUIPPED (SERIES 110, 111 AND
RETROFIT) MODELS
STEP 8 DAMPER INPUT TEST
STEP 8. DAMPER INPUT TEST.
Test for 24 VAC between the yellow wire on the PC
board and ground. Effikal – Check from orange wire to neutral
IF THEN
24 VAC is not present:
Check the black wire connections
between the PC board and high limit.
24 VAC is present
Go to step 6.
STEP 9 TEST THE DAMPER
STEP 9. TEST THE DAMPER
. Visually check the damper blade position.
IF THEN
The damper does NOT open fully:
Replace the damper assembly
The damper DOES open fully:
Go to step 10.
Test from
Orange
wire to
Black
(neutral)