A.O. Smith 120 trough 500 Water Heater User Manual


 
BTR TANK TYPE HEATERS
SERVICE HANDBOOK
A.O. Smith Water Products Service Handbook
Irving, Texas ©2000 Training Department
19
TROUBLESHOOTING BTR WATER HEATERS
To troubleshoot a BTR water heater check that:
120 VAC is supplied to the heater
the tank is full of water
gas is supplied to the unit
STEP 1 TEST THE TRANSFORMER
STEP 1 - TO TEST THE TRANSFORMER
- Using a multimeter, test for 24 VAC
between the secondary transformer terminals.
IF THEN
The meter does not read 24 VAC:
Check that the 120 VAC is supplied
from the On/Off Switch – if not, replace
switch.
Check that the 120 VAC is supplied
from transformer.
The meter reads 24 VAC:
Go to step 2.