Annovi Reverberi RK 1450 rpm N Version Water Pump User Manual


 
First Choice When Quality Matters
NORTH
AMERICA
Plunger Pumps
Operating Instructions and Parts Manual RK Series Pumps
Please follow these easy steps to adjust the
pressure:
Step 1: Remove black cap (pos. #1) from knob.
Step 2: Loosen bolt (pos. #2) with 6mm hex
wrench.
Step 3: Loosen nut (pos. #3) to top of (pos. #2)
bolt.
Step 4: Turn the black knob (pos. #4) clockwise
until it stops.
Step 5: Start machine hold trigger on open
position and turn (pos. #2) bolt
until no further increase of pressure is
noticed, continue to hold
trigger open and turn counter-
clockwise until a slight drop in
pressure is felt.
Step 6: Spin (pos. #3) nut down. While holder
(pos. #2) bolt
in place with hex wrench, use special
tool (AR1560590)
Or extended 13mm socket wrench to
hand tighten
(pos. #3) nut against (pos. #4) black
knob.
Instructions for Adjusting Gymatic Unloader Valves
4
3
2
1
AR1560590
Nut holder for adjusting Gymatic Unloader
Mounting Bolt Torque Specifications
Inlet 354 in/lbs 30 ft/lbs
Discharge 221 in/lbs 19 ft/lbs
Step 7: Replace (pos. #1) black cap.
NOTE: Now pressure can be decreased by
turning black knob (pos. #4) counterclockwise,
but the pressure cannot be increased to a rating
higher than what max is set at by technician.