5. INSTALLATION CONSIDERATIONS
LOCATION
The Well-X1
is designed for indoor and outdoor installations. The NEMA 3R enclosure can be installed
in direct weather. If installed outdoors, be sure the following conditions are met:
Do not install where ambient temperatures can drop below freezing
or exceed 120° F.
Ensure a Tuf Kote
model is selected (Example: WX1-302TK)
for outdoor installations. This proprietary coating is specifically
designed to withstand outdoor applications.
Use water-tight: wiring conduit, wire nuts and conduit connections
as dictated by applicable codes and ordinances.
Protect the piping from mechanical damage.
Install the relief valve blow down tube where venting water will not
cause personal injury or damage the surrounding property.
Drip Pan and Drain: To avoid leaking and/or property damage,
install with a drip pan connected to an adequate working drain
kept clear at all times.
ORIENTATION
Ensure the installation meets all applicable local codes and is installed by a qualified professional.
Additionally, the following should be noted.
This unit is designed for vertical installation above ground only.
Do not install horizontally or directly bury the unit. The Well-
X1
may be installed below grade in a well pit or other suitable
enclosure. Do not locate in an area where leaking or flooding
could cause property damage to surrounding areas.
Check codes to determine if there are any height requirements
pertaining to the Well-X1
.
Particularly, ensure the bottom
drain meets these requirements. If restrictions are imposed on
the proximity of drain connections to the floor, the unit may be
elevated on blocks or the bottom drain tube can be removed
and plugged, after which a sampling tap may be installed in the
water lines near the top of the Well-X1
.