American Standard 7056.105 Plumbing Product User Manual


 
FAQ' S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the sensor range?
A: Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1 800-442-1902.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging from 20-80 psi.
7
CAUTION
GENERAL CLEANING; Fig. 14
1. For general cleaning use a damp, soft cloth to clean
the spout and the sensor.
2. For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.
Do not scratch the sensor when cleaning.
Avoid using anything that may scratch the spout
surface. Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.
8
M965255 REV. 1.6
1. Remove the FAUCET COVER (1) by unthreading the
LEVER SCREW (2) and pulling off the LEVER
HANDLE (3). Unthread the FAUCET COVER SCREW
(4) at the back of the FAUCET. Pull FAUCET COVER
(1) up and off. See Fig. 2 in this section.
2. Replace LEVER HANDLE and rotate
counter-clockwise to its stop position (100% cold).
Remove HANDLE.
3. Pull out LIMITER STOP (1) from the VALVE STEM (2).
4. Rotate LIMITER STOP (1) 180 degrees and insert
back onto VALVE STEM (2).
5. Replace FAUCET COVER (1) and LEVER HANDLE
(3). Install LEVER HANDLE SCREW (2), FAUCET
COVER SCREW (4) and tighten. See Fig. 2 in this
section.
CHANGE HOT LIMIT SETTING
FROM 95% TO 85%; Fig. 13
7
3
9
8
1
2
ROTATE 180˚
SLOT
SLOT
Fig. 13
Fig. 14