Fig. 1e
8
10
ELECTRICAL INSTALLATION
M965274
4
Fig. 1
Fig. 1b
1. Remove ENCLOSURE COVER (1). Fig. 1.
2. Feed the WIRE CONNECTORS (2) through the top
of ENCLOSURE (5). Fig. 1a.
3. Remove GROMMET (4) from ENCLOSURE (5). Fig. 1.
4. Feed the gray SENSOR WIRE (7) through
GROMMET (4), 4" from CONNECTOR. Fig. 1b. Insert
gray SENSOR WIRE (7) into SPLIT PLUG (9). Push
SPLIT PLUG (9) into GROMMET (4) to seal. Fig. 1d.
5. Insert GROMMET (4) back into ENCLOSURE (5).
Fig. 1c.
6. Install CIRCUIT BOARD (3) into ENCLOSURE (5)
with SENSOR WIRE (7) under BOARD. Fig. 1c.
7. Insert SENSOR WIRE CONNECTOR (8) and
EXTENSION WIRE CONNECTOR (11) into available
CIRCUIT BOARD RECEPTORS (10) slots. Fig. 1e.
8. Connect wires from SENSOR to SOLENOID VALVE
(6) (Red to +, Black to -). Fig. 1d.
9. Replace ENCLOSURE COVER (1). Tighten cover
screws firmly.
10. Contractor to supply ELECTRICAL BOX (12)
and connection to ENCLOSURE (5). Mount POWER
SUPPLY (13) into ELECTRICAL BOX (12). Connect
White and Black power connections to POWER
SUPPLY CABLE (14). Fig. 1f.
11. Connect the EXTENSION WIRE (16) to the
POWER SUPPLY CABLE (15). FIG. 1f.
ELECTRICAL CONNECTIONS; Fig. 1
1
4
8
RED
6
Fig. 1c
Fig. 1d
7
4
9
1
4
7
5
4
4"
3
CAUTION
Before opening ENCLOSURE
disconnect AC power supply.
BLACK
F
5
2
Fig. 1a
5
7
10
11
Fig. 1f
BLACK & WHITE
POWER
CONNECTIONS
15
13
CONNECTOR NOT
USED IN THIS
INSTALLATION
16
14
4" ELECTRICAL BOX
OR EQUIVALENT BY
OTHERS
12