Selection of installation positions for indoor unit
*
* To be installed at the position where the air delivered from the unit can reach every corner of
the room;
* To avoid being affected by the outdoor air;
* To avoid blockage to the air inlet or outlet of the unit;
* To avoid too much oil smoke or steam;
* To avoid possible generation, inflow, lingering or leakage of flammable gases;
* To avoid high-frequency facilities (such as high frequency arc welders, etc.);
* To avoid the places where acid solutions are frequently used;
* To avoid the places where some special sprayers (sulfides) are frequently used.
* Not to install a fire alarming device near the air outlet of the unit (during operation, the fire alarm
device might be erroneously triggered by the warm air from the unit);
INSTALLATION & REPAIR GUIDE
Split Wall-Mounted Air Conditioner
Above 100mm(4")
Left side: 150mm(6")
and above
Right side: 150mm (6")
and above
Ceiling
Wall hanging plate
ground
2300mm(7'6")
and above
*
Make sure of enough space for installation and maintenance.
* To take into consideration the operational convenience and safety in installation, it is recommended
to ensure enough space between the unit and the walls.
*
Height limits of indoor and outdoor units.
* Either the indoor unit or the outdoor unit can be higher, but the height difference must comply the stated
requirements.
* Try to reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the
performances of the units.
Indoor unit
outdoor
unit
5m(16'5")max.