Amcor 9000E Air Conditioner User Manual


 
11
TECHNICAL DATA
Model 9000E 12000E 15000E
9000EH 12000EH 15000EH
Cooling capacity *
BTU/h 7000 9000 12000
kW 2 2.6 3.5
Power consumption -Cooling
-Heating (EH only)
880 1100 1330
W 1700
1600
A
4 5 6
R407C / 570 R407C / 650
-heating element (EH only)
Current -Cooling
7.5
-Heating (EH only)
Mains V / Hz / PH 220 - 240 / 50 / 1
Compressor model rotary
Fan speeds 3 (2+1 turbo)
Thermostatic range °C 18 - 32
Refrigerant
charge type / g R407C / 480
Dimensions
(w x h x d) mm 555 x 800 x 455
Net weight kg 31.5 34 39
* measured conform EN 14511.
Subje
ct to modifi cations without prior notice. For greater precision, please refer to the rating label placed on
the
product.
Empty the internal water container.
Clean
the screen filter.
Rem
ove 3M Filtrete™ filter and active carbon filter.
• Remove the 3M Filtrete™ filter and active carbon filter before end of season storage and
install
new filters at the beginning of the new season.
The old filters can be disposed of in the ‘Non-biological rubbish
container’.
• Replacement filter packages are available from Amcor.
Put the unit in Fan Only mode for a few hours to ensure that the inside
be
comes completely dry.
Store the cable as shown.
Protect the unit against dust and store in a dry place, not accessible to children.
STORAGE
Reminder:
Waste electrical products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.