Amana AMV90453BX Furnace User Manual


 
11
PRODUCT DESIGN
Thermostats:
The following Amana® brand thermostats are suggested for use with AMV9 & ACV9 Furnace Models:
Thermostat Man/Auto Programmable Cool Heat Batt. Powered Batt. Bkup
1213406* Man. Or Auto Yes 2 3 No No
1213407
Man. Changeover Yes 2 2 Yes Yes
1213411
Man. Changeover No 2 2 Yes No
THERMOSTATS
*1213406 is the recommended model for the AMV9 & ACV9 furnaces when used with a heat pump in a fossil fuel
application. It is NOT for use with either the AMV9 or ACV9 as a sole heating source. 1213406 thermstats are 24V
powered with battery backup.
Filters:
Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or
CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty
Upflow Filters
This furnace has provisions for the installation of return air filters at the side and/or bottom return. The furnace will
accommodate the following filter sizes depending on cabinet size:
Cabinet
Width
(in.)
Nominal
Filter Size
(in.)
Approx.
Flow Area
(in
2
)
Cabinet
Width
(in.)
Nominal
Filter Size
(in.)
Approx.
Flow Area
(in
2
)
All 16 x 25 x 1 400 17-1/2 14 x 25 x 1 350
21 16 x 25 x 1 400
24-1/2 20 x 25 x 1 500
BOTTOM RETURNSIDE RETURN
Refer to Minimum Filter Area tables to determine filter area requirement. NOTE: Filters can also be installed elsewhere
in the duct system such as a central return.
Disposable Minimum Filter Area (in
2
)
[Based on a 300 ft/min filter face velocity]
*Minimum filter area dictated by heating airflow requirement.
*Minimum filter area dictated by heating airflow requirement.
Permanent Minimum Filter Area (in
2
)
[Based on 600 ft/min filter face velocity]
600 800 1000 1200 1400 1600 2000
0453__X* 376* 384 480 576 --- --- ---
0704__X* --- --- 564* 564* 672 768
0905__X* --- --- --- 752* 752* 768 960
1155__X* --- --- --- 940* 940* 940* 960
600 800 1000 1200 1400 1600 2000
0704__X* --- --- 641* 641* 672 768 ---
0905__X* --- --- --- 854* 854* 854* 960
Input__Airflow
UPFLOW
COOLING AIRFLOW REQUIREMENT (CFM)
COUNTERFLOW
COOLING AIRFLOW REQUIREMENT (CFM)
Input
Airflow
600 800 1000 1200 1400 1600 2000
0453__X* 376* 384 480 576 --- --- ---
0704__X* --- --- 627* 627* 672 768 ---
0905__X* --- --- --- 836* 836* 836* 960
1155__X* --- --- --- 940* 940* 940* 960
600 800 1000 1200 1400 1600 2000
0704__X* --- --- 320* 320* 336 384 ---
0905__X* --- --- --- 427* 427* 427* 480
Input__Airflow
UPFLOW
COOLING AIRFLOW REQUIREMENT (CFM)
COUNTERFLOW
COOLING AIRFLOW REQUIREMENT (CFM)
Input
Airflow