Operation
Vent Control
Open or close the vent by sliding the vent control lever to the
appropriate setting.
EXHAUST - This setting opens the vent to move indoor air
out.
Note: To conserve energy, the unit should be set to the
FAN ONLY mode when using this setting.
CLOSED - In this position the vent is closed and room air is
recirculated and filtered. This position should be used for all
normal cooling operations (see underlined cooling options
on control panel).
Unit Control
ENERGY SAVER (HIGH, MED and LOW) -
ENERGY SAVER mode provides the most
energy efficient use of your room air condi-
tioner. In ENERGYSAVERmode, thefanstopswhenthe
compressor stops cooling. This feature can be used with
SMART COOL or cooling with any fan speed.
Amana's new air sampling system works to maintain set
temperature within 1.5°F while in ENERGY SAVER mode.
Approximately every 5 minutes the fan will turn on and
"sample" the room air todetermine ifcooling isneeded. Ifthe
room is cool enough, the fan will cycle off. If the room needs
further cooling, the cornpressor will start along with the fan
until the set temperature is reached.
ENERGY SAVER has a soft start fan feature. This feature
starts the fan in low speed to reduce noise.
FAN ONLY- FAN ONLY circulates room air at
the set fan speed without cooling. This feature
can be turned off by pressing the FAN ONLY,
the SMART COOL, or the ENERGY SAVER button. Indoor
temperature is displayed in FAN ONLY mode.
Control Panel
[_ OFF - Completely shuts off the unit.
SMART COOL- SMART COOL adjusts the
fan speed of the unit to achieve the selected
temperature. The SMART COOL feature uses
computer logic to cool the room quickly and
quietly. The fan speed starts on high, automatically switches
to medium, and finally goes to low as the room temperature
nears the set temperature.
__ LOW FAN, MED FAN, HIGH FAN
- These three buttons are used to
select either a low, medium or high
fan speed to cool. If FAN ONLY is selected these buttons
change fan speed without cooling. Selecting the fan speed
starts normal cooling.
SET Temperature - These key pads in-crease or decrease the set temperature.
DELAY TIMER- This button provides a means
of delaying the start up or shut down of the air
conditioner from 1 to 24 hours from the present
time. After setting the delay timer, the displayed time will
countdown to unit start or stop, See next page for details,
[_ _ _sriogmhetnme:dAsdlU_stiFp/atybeght.
ness can be changed using the "up" or "down" keypad. To
decrease brightness, simultaneously press and hold OFF
pad with "down" arrow. To increase brightness, simulta-
neously press and hold OFF pad with "up" arrow.