Nilfisk-ALTO 2000 Vacuum Cleaner User Manual


 
AMERICAN-LINCOLN TECHNOLOGY 1 - 17
SMART 2000
Figure 10
Figure 11
Figure 9
FILTER SHAKER SWITCH (See Figure 9)
The filter shaker switch is located on the top left corner of
the instrument panel . By pressing and holding in the
lower part of the switch, it will activate the filter shaker
motors for 20 to 30 seconds. Upon releasing the switch,
it will return to the off (middle) position.
The Impeller fan will stop when the filter shaker has been
activated. The filter shaker will only operate with the
hopper in the “DOWN” position.
DUST CONTROL SWITCH (See Figure 9)
The Dust Control Switch located on the top left corner of
the instrument panel. To turn on the dust control system
for “NORMAL” sweeping, press in the upper portion of the
switch. To turn off the dust control system for sweeping in
wet conditions, return the switch to the middle position
(wet sweep bypass). This will prevent the filter from being
damaged by water pickup while sweeping.
SIDE BROOM and MAIN BROOM SWITCH (See
Figure 10)
The Side and Main Broom Switch is located to the right of
the steering column. By pressing in the upper portion of
the switch, the side and main broom are raised and
turned off. To lower and turn on both brooms, press the
lower portion of the switch.
MAIN BROOM ADJUSTMENT (See Figure 11)
The main broom adjustment knob for changing the sweep
height to compensate for broom wear, is located in front
of the machine to the right of the filter. Turning the knob to
the left (counterclockwise) will lower the main broom.
SIDE BROOM ADJUSTMENT (See figure 11)
The side broom adjustment knob for changing the sweep
height to compensate for broom wear, is located in front
of the machine to the right of the filter. Turning the knob to
the left (counterclockwise) will lower the side broom.
OPERATION OF CONTROLS AND GAUGES - Cont.