8 Troubleshooting
Fault Cause Remedy
Motor does not start > Fuse in mains plug has
blown.
> Overload protection switch
has tripped.
Reset the fuse.
Switch off the vacuum
cleaner and allow it to cool
for approx. 5 minutes. If it
can not be started again,
contact the Alto service
department.
Motor does not run in
automatic mode
1)
> Power tool is defective or not
connected properly.
Check that the power tool
works or that the plug is
inserted correctly.
Acoustic warning
1)
is heard
(reduced suction power)
> Suction power selected with
suction power control
1)
is too
low.
Set suction power in accord-
ance with section 4.2.3.
"Suction power control".
No suction power during wet
cleaning
> Tank is full (floater closes the
suction opening).
Switch off the cleaner. Empty
the tank.
Voltage fluctuations
> Impedance of power supply
is too high.
Connect the cleaner to
another socket closer to the
fuse box. Voltage fluctua-
tions over 7 % should not
occur if the impedance at
the transfer point is
0.15 .
> Hose diameter does not
correspond to suction hose
diameter setting.
Set suction hose diameter
setting
1)
to correspond to
hose diameter.
> Clogged suction hose/
nozzle.
Clean suction hose/nozzle.
> Seal/tank rim between the
upper section of the cleaner
and the dirt tank is dirty/
defective.
Clean/replace seal.
> Filter bag is full. See section 7.2.2 "Replacing
the filter bag".
> Filter element is clogged. See section 4.4 "Cleaning
the filter element" and 7.2.3
"Replacing the filter ele-
ment".
1)