Nilfisk-ALTO 661BL Carpet Cleaner User Manual


 
28 SCRUBTEC 653B – 653BL – 651BCL – 661BL 9097058000(2)2009-10 A
ENGLISH USER MANUAL
FUSE CHECK/REPLACEMENT
Disconnect the battery connector (12).1.
Move aside the recovery water drain hose (16).2.
Remove the battery charger cable (I, Fig. 10), if equipped, from the cable holder (J).3.
Remove the screws (A) and carefully move aside the panel (B) by disengaging the grommet (K) from its housing on the panel 4.
(B).
Check/replace the following fuses:5.
Brush deck fuse F1: (40 A)(5a)
Vacuum system fuse F2: (30 A)(5b)
Drive system fuse F3: (30 A) (*)(5c)
Signal circuits fuse F4: (3 A)(5d)
Brush/pad-holder release fuse F5: (20 A)(5e)
Pump fuse F6: (3 A)(5f)
Only for SCRUBTEC 653BL, SCRUBTEC 651BCL, SCRUBTEC 661BL(*)
Perform steps 1 to 4 in the reverse order.6.
A
A
A
A
K
I
J
F
G
H
E
D
C
P100120
Figure 10