Nilfisk-ALTO 40 Vacuum Cleaner User Manual


 
9
CENTIX 60
CENTIX 60 PREMIUM
english
1
2
3
4
Fault Cause Remedy
Motor does not start. > Fuse of the mains socket has
blown
Reset the fuse
> Plug not inserted for opera-
tion on the central extraction
system/mobile operation
Insert the plug into the clea-
ner socket. See sections 4.1.3
and 4.1.4
> Overload protection switch
has tripped
Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner can-
not be started again, contact
the Alto service department.
Motor runs continuously > Plugs for mobile operation
and for central extraction sys-
tem are both inserted
• Insert only one of the two
plugs into the cleaner socket
Reduced suction power > Clogged suction hose/nozzle Clean suction hose/nozzle
> Seal/tank rim between the up-
per section of the cleaner and
the dirt tank is dirty/defective
Clean/replace seal
> Filter bag is full See section 7.2.2 „Replacing
filter bag“
> Filter element is clogged See section 7.2.3 „Replacing
filter bag“
-->
7.2.3 Replacing the filter
element
1. Remove the upper section of
the cleaner from the dirt tank
and deposit it with the filter
element facing upwards. Do
not place the upper section
of the cleaner on the guard
(1).
2. Turn the filter holder anticlo-
ckwise (2) and remove it (3).
3. Carefully remove the filter
element.
4. Clean the filter seal (4).
Check it for damage and
replace it if necessary.
5. Fit a new filter element.
6. Fit the filter holder and turn it
clockwise to secure it.
7. Dispose of the used filter
element in accordance with
legal regulations.
CAUTION:
Never use the vacuum cleaner
without a filter.
8 Troubleshooting