Nilfisk-ALTO 30 H Vacuum Cleaner User Manual


 
23
english
ATTIX 30/50 H/M
3
2
2
7
3
6
3
8
ø
ø
ø
ø
7.2.6 Replacing filter element
"H" (Xtreme Clean
System)
During the following work, ensure
that dust is not unnecessarily
spread around, Wear a P2 breath-
ing mask.
CAUTION! In the case of asbestos
abatement wear additional single-
use clothing.
Never use the vacuum cleaner
without a filter.
A
A
1. Switch off the vacuum clean-
er and pull the mains plug
out of the socket.
2. Open the retaining clamps
(A) and remove the upper
section of the vacuum clean-
er.
Removing the filter elements:
3. Unscrew the screw and open
filter tension part (B).
4. Remove carefully the cas-
settes with filter elements.
5. Place the protective filter
bag over the filter element.
6. Carefully remove the filter
element and close the pro-
tective filter bag with a knot.
7. Dispose of the used fil-
ter element in acordance
with legal regulations.
Inserting the filter elements:
8. Insert new filter elements (C)
into the cassettes (D).
9. Attach the cassettes with the
filter elements onto the up-
per section of the vacuum
cleaner.
10. Fix the filter tension part (B)
and attach the screw.
B
B
B
C
D