22
ATTIX 30/50 H/M
english
3
2
2
7
3
6
3
8
ø
ø
ø
ø
7.2.5 Replacing filter element
"H" (Push & Clean
System)
During the following work, ensure
that dust is not unnecessarily
spread around, Wear a P2 breath-
ing mask.
CAUTION! In the case of asbestos
abatement wear additional single-
use clothing.
Never use the vacuum cleaner
without a filter.
3
2
2
7
3
6
3
8
ø
ø
ø
ø
A
A
A
A
1. Switch off the vacuum
cleaner and pull the mains
plug out of the socket.
2. Open the retaining clamps
(A) and remove the up-
per section of the vacuum
cleaner.
Removing the filter element:
3. Using the enclosed tool (C),
turn the filter holder (D) anti-
clockwise and remove it.
4. Carefully remove the filter
element.
5. Clean the filter seal (B).
Check it for damage and re-
place it if necessary.
6. Place the protective filter
bag over the filter element.
7. Carefully remove the filter
element and close the pro-
tective filter bag with a knot.
8. Dispose of the used filter
element in accordance with
legal regulations.
Inserting the filter element:
9. Using the enclosed tool,
attach the filter holder and
turn it clockwise to lock it.
10. Attach the upper section of
the vacuum cleaner.
11. Close the retaining clamps
(A). Ensure that the retain-
ing clamps fit properly.
C
D
B