Air-O-Swiss AOS E2251 Humidifier User Manual


 
20
Water purification
An Ionic Silver Stick
®
(19) keeps the water free of harmful
bacteria. The anti-microbial action of silver is used. The
Ionic Silver Stick
®
releases silver ions in the water over a
long period (approx. one year). It is self-cleaning and main-
tenance-free.
Positioning the appliance:
Fig. 19 shows the position in the appliance. Remove the
Ionic Silver Stick
®
from the packaging and place it between
the evaporating mat and the tray edge without it impairing
the tank when inserted (see Fig. 19). Please replace the
Ionic Silver Stick
®
at the latest after one year; a new one
can be purchased from a specialist shop.
Use of additives
Water additives (ethereal/essential oils, fragrances, euca-
lyptus, water conditioners etc.) must not be used! Even a
small amount can cause cracks in the tank material. The
material isn’t made for the use of such additives. One drop
is enough to damage the tank and as a consequence the
unit. Any use of such additives will void the manufacturer’s
warranty.
en
Operating AOS E2241 (20)
Turn the level switch to the desired setting. In order to
achieve rapid humidification set the switch to «HI». For
quiet, night operation or a gradual increase in humidity set
it to «Quiet Mist». The operating display «Power» comes on
when the appliance is switched on.
Operating AOS E2251 (21)
Turn the level switch to the desired setting. In order to
achieve rapid humidification set the switch to «HI», for
normal operation «MED». For quiet, night operation or a
gradual increase in humidity set it to «Quiet Mist». The
operating display «Power» comes on when the appliance
is switched on.
Setting the hygrostat on the AOS E2251 (21)
The electronic hygrostat enables the setting of the desired
humidity (selectable between 20% - 90%). The appliance is
then automatically controlled. The desired humidity can be
set by pressing the
and
symbols.
As soon as the measured humidity is 2% below that desired,
the appliance switches on automatically. Once the set
humidity level has been achieved the fan blade is switched
off and the appliance remains active in Standby mode.
The current humidity level is displayed in large numbers,
the smaller number indicate the desired level.
If the current humidity falls below 20%, the display in-
dicates «LO». Should the humidity exceed 90% the symbol
«HI» appears.
19 20 21