Air-O-Swiss AOS E2251 Humidifier User Manual


 
26
Maintenance
While in operation
Check the water level in the water tank regularly,
Refill the water tank in good time.
Every 3 years, replace the sealing ring on the bayonet cap
for the water tank.
Repairs are only to be conducted by specialists or customer
services.
Storing the appliance
Clean the humidifier as described earlier and dry it
thoroughly. Preferably store the appliance in its original box.
Avoid high temperatures.
Disposal
Return your worn out humidifier to your dealer for proper
disposal. You can obtain information on other ways to
dispose of the humidifier from your local council.
Warranty
The warranty conditions are defined by our representative
in the country of sale. Please contact your dealer if, despite
strict quality control, your humidifier becomes defective.
You must present the receipt when making a claim under
the warranty.
Legal notice
The appliance is CE-certified and complies with the
Directives
73/23/EWG concerning for electrical safety
89/336/EWG and 92/31/EWG concerning electro-
magnetic compatibility
The right to make technical modifications is reserved. The
instructions for use are protected by copyright.
Technical data AOS E2241
Mains voltage 230 V / 50 Hz
Power consumption Level I/II 19 W / 45 W
Humidity output Level I/II 350 g/h / 510 g/h
Suitable for rooms up to 85 m
2
/ 215 m
3
Water capacity 5.7 litres
Dimensions 445 x 237 x 280 mm
Weight (empty) 3.6 kg
Operating noise level < 39 dB(A)
Accessories Evaporationg mat
Ionic Silver Stick
®
(optional) Hygrostat
Technical data AOS E2251
Mains voltage 230 V / 50 Hz
Power consumption Level I/II/III 20 W / 28 W / 45 W
Humidity output Level I/II/III 410 / 530 / 600 g/h
Suitable for rooms up to 110 m
2
/ 275 m
3
Water capacity 6.9 litres
Dimensions 445 x 237 x 335 mm
Weight (empty) 3.9 kg
Operating noise level < 37 dB(A)
Accessories Evaporationg mat
Ionic Silver Stick
®
en
Trouble shooting
Problem Possible cause What to do
Motor not running Mains cable not plugged in Connect to the mains
Indicator on rotary switch not illuminated Rotary switch in position (OFF) Place rotary switch in position
(QUIET MIST/MED/HI)
Motor not running; indicator Motor defective Contact customer service
on rotary switch illuminated
Rotary switch cannot be turned Rotary switch defective Contact customer service
Humidifier performance inadequate Evaporating mat exhausted Replace evaporating mat
Base tray flooded Seal on water tank defective Order spare part and replace seal
Cracks or fractures in plastic parts Transport damage or improper use Order spare parts or contact customer service