Aico Ei261ENRC Carbon Monoxide Alarm User Manual


 
Note: When the second sensor has completed its 5 years of operation the amber light will flash every 40
seconds. The sensor module can only be replaced once. The entire unit must be replaced after 10 years.
The date for replacing the entire unit is given on the ‘REPLACE UNIT BY’ label on the alarm.
8. LIMITATIONS OF CO ALARMS
- The Ei261EN/261DEN CO Alarm will not work without mains power if the rechargeable cells are
depleted. The green power light indicates that the Alarm is receiving mains power.
- Carbon Monoxide must enter the unit for it to be detected. There may be Carbon Monoxide in other
areas of the house (e.g. downstairs, in a closed room etc) but not in the vicinity of the CO Alarm. Doors,
air draughts and obstructions can prevent the CO from reaching the Alarm. For these reasons we
recommend CO Alarms are fitted both near and in bedrooms, particularly if bedroom doors are closed
at night. Additionally install in rooms where members of the household spend much of their time, and in
rooms with potential sources of CO gas.
- The CO Alarm may not be heard. The sound output is loud but it may not be heard behind a closed door
or if it is too far away. Interconnecting CO Alarms greatly improves the probability that they will be heard.
The Alarm may not wake up somebody who has taken alcohol or drugs. The alarm sound may be masked
by other sounds such as T.V., stereo, traffic noise etc. Fitting CO Alarms on either side of closed doors will
improve their chance of being heard. This CO Alarm is not designed for people with impaired hearing.
- CO Alarms don’t last indefinitely. CO Alarms are sophisticated electronic devices with many parts.
Although the alarm and its component parts have undergone stringent tests and are designed to be very
reliable, it is possible that parts can fail. Therefore, you should test your CO Alarm weekly. The CO Alarm
sensor must be replaced after 5 years operation. The complete unit must be replaced after 10 years.
- CO Alarms are not a substitute for life insurance. House-holders are responsible for their own
insurance. The CO Alarm warns of increasing CO levels, but we do not guarantee that this will protect
everyone from CO poisoning.
24
B16132-R0-261ENRC-UC-ENG 7/11/07 11:52 AM Page 24