Aico Ei261ENRC Carbon Monoxide Alarm User Manual


 
15
4. INSTALLATION
The Alarm is designed to be permanently
mounted, using its own built-in terminal
block to connect it to the mains wiring. The
mounting plate can be screwed directly to
the ceiling/wall. Alternatively it can be
screwed to a standard junction box (BS
4662 single gang accessory box). The alarm
requires a current of 60mA. The Alarm must
not be exposed to dripping or splashing.
There are important markings on the
underside of the alarm.
IMPORTANT PRECAUTION: Do not install
the actual alarm itself in new or
renovated buildings until all work is
completed (including floor coverings)
and the building has been fully cleaned.
The wiring can be installed when
appropriate. (Excessive dust and debris
from building work can contaminate the
sensor and cause problems, it will also
invalidate the guarantee). If it must be
installed, cover it completely, particularly
around the edges, with a suitable
covering, until all cleaning is finished.
LOCATION FOR
TAMPERPROOF SCREW
(see page 16)
PUSH SMALL SCREWDRIVER
STRAIGHT IN TO RELEASE.
PUSH COVER AWAY FROM
SCREWDRIVER
WARNING: DISCONNECT MAINS BEFORE REMOVING ALARM FROM
CEILING OR WALL
TAMPERPROOF CATCH
MOUNTING PLATE
SIDE VIEW
GAS ENTRY HOLES
Figure 4 - Alarm Installation
B16132-R0-261ENRC-UC-ENG 7/11/07 11:52 AM Page 15