AEG 3531 WK-M GB 949600835 Burner User Manual


 
15
Caution: In order to avoid a hazard this
appliance must be installed according
to these instructions for installation
The hob unit can be mounted in any
type of kitchen with a table surface
whose thickness is between 28 mm
and 40 mm.
Headroom
The distance to any shelves or tops of
a cabinet under the hob is to be at least
55 mm.
Fixing
Screw the fixing brackets out to such
an extent that they can be turned in
under the table top. Tighten the
brackets on to the table top with an
ordinary screwdriver.
Cut-out measurements
One rectangular hole is sawn out for
the hob combination chosen.
The depth of the cut-out for any unit
is: 490 mm
Length of hole = sum of all units`
externally measured length, less 20
mm.
Mounting of Reinforcement
Beams
A reinforcement Beam, with
supporting flanges at each end, is
included with each two-burner unit.
For unit combinations, a reinforcement
beam must be used between each unit.
MIN 55
Mounting
Minimum distance
to side wall:
150 mm
Minimum distance to
rear wall (non
flammable material):
50 mm
Reinforcement
beams