Addtron Technology P201 Vacuum Cleaner User Manual


 
TROUBLESHOOTING
Machine does not run.
The circuit breaker has tripped. Allow the circuit breaker 2 minutes
to cool before resetting.
Plug is broken or has loose contact. Replace.
Prevent circuit overload.
Check the pad and change it if it is rough or dirty.
Spray buffing or spray cleaning is not a substitute for scrubbing or
mopping a floor. Prepare the floor surface before spray buffing.
Eliminate any extension cord that is smaller than 12/3 wire or
greater than 25 feet in length.
Unplug anything other than the machine from the circuit or locate
another circuit.
Machine will not start.
Circuit breaker is not reset. Reset breaker.
Plug is broken or has a loose contact. Replace.
Circuit breaker is defective or weak. Replace.
Switch is defective. Replace switch.
Rectifier is defective. Replace rectifier (P202 and P172 only).
Machine will not reach operating speed.
Unplug anything else other than the machine from the circuit or
locate another circuit.
Motor runs but pad or brush does not turn.
Coupling is broken. Replace. Coupling is not covered under war-
ranty. Do not attempt to place a running machine over a block or
brush. Always place and remove the block or brush by hand.
WARNING
TO AVOID FIRE, DO NOT USE WITH A FLAMMABLE
OR COMBUSTIBLE LIQUID TO CLEAN FLOOR.
X8444
ONE LAST REMINDER! READ ALL INSTRUCTIONS,
WARNINGS AND CAUTIONS BEFORE USING EQUIPMENT.
These guidelines are presented for your protection and convenience. Please read them carefully, since a failure to heed these precautions
could result in discomfort or injury. When using an electrical appliance, basic safety precautions should always be followed.
SAFETY INSTRUCTIONS
This Floor Machine should be grounded while in use to protect the
operator from electric shock. This machine is equipped with a 3-
conductor cord and a 3-prong grounded type attachment cap plug
to fit the proper grounding type receptacle. The green (or green
and yellow) conductor in the cord is the grounding wire. Never
connect this wire to anything other than the grounding blade.
The Floor Machine is provided with an attachment cap plug, as
shown in Sketch A, and is intended for use on a nominal 120 volt
circuit. If a properly grounded receptacle, as shown in Sketch A, is
unavailable, an adaptor, as shown in Sketch C, is available and
should be installed, as shown in Sketch B, if the outlet box that
houses the receptacle is grounded. Be sure to fasten the grounding
tap to the faceplate screw.