Aarrow Ecoburn Wood & Multifuel Stoves 27
OPERATING INSTRUCTIONS
AIR INLET CONTROLS
Both Aarrow Ecoburn wood & multifuel stoves
have two air inlets:
•The primary air inlet providing under draught to
the base of the fire chamber through the control
slider located under the oval cover.
•The air wash system (so called because its
pre-heated high speed air washes across the inner
face of the door glass, keeping it clear), which
provides over draught.
PRIMARY AIR
Air enters the appliance through the control on the
bottom of the fire door. The Aarrow Ecoburn has a
single control knob which slides left to right.
Sliding the knob to the right (+), fig.21, will
increase the amount of air intake to the stove. To
decrease push knob to the left (-) as in fig. 20.
AIRWASH SYSTEM
The air wash has an internal sliding plate with slots,
housed in a cover plate, and is located above the fire
door. Sliding the control knob to the right as far as it
will go achieves the fully open position. Sliding it to
the left will shut off the air inlet slots As shown in fig.
22 & 23.
Please Note - refer to page 26 to the type of
fuel being burnt, as the position of the air inlet con-
trols are dependant upon the fuel varity being used.
Incorrect setting could cause an inefficient heat out-
put and poor fuel consumption from the appliance.
FUEL RETAINER BARS
Fuel retainering bars are supplied with the stove.
For wood burning, the top fuel retaining bar may be
removed to afford a better view of the fire. Slide
and lift the bar until it is clear of the guides at each
side, and remove through the fire door opening.
The bars are symmetrical and of even lengths
making incorrect fitting impossible.
Note: This operation should only be carried out
when the appliance is unlit and cold.
Fig. 20 Closed Position
Fig. 21 Open Position
Fig. 22 Fully Closed
Fig. 23 Fully Open