![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/88/6887b55f-afe9-42d8-be27-d0fb4f6436f3/6887b55f-afe9-42d8-be27-d0fb4f6436f3-bg5.png)
9
n
Install duct throuah the vent
opening in upper cabinet or wall.
Complete venting system according to
method needed. See “Venting
requirements.” Use caulking to seal exterior
wall or roof opening.
10V
W If roof or wall cap does not
Numbers
corresoond
to steyjs.
To install a non-vented
have a damper, attach rectangular damper
supplied with hood
to selected rectangular
vent opening. If damper is attached to
back of range hood, be sure damper hinge
is toward the top.
If roof or wall
cap
does not have a damper
and round duct is used,
install damper
(supplied with hood) in duct to prevent air
from flowing back into duct.
If roof or wall cap has a damper,
Do not
use damper blade supplied with range
hood.
(recirculating-only)
model:
-
3a
H Remove knockout from the
wiring opening (rear or top) to be used.
The range hood cabinet may have venting
knockouts.
Do not remove these venting
knockouts.
The model
cannot
be vented.
I
I
from wall,
I
(not
I
cabinet
I
frame)
11
n
Run wirina throuah wall or
cabinets according t&-the N%ional
Electrical Code and local codes and
ordinances.
Do not turn on power until
installation is complete.
Use caulking to seal
ceiling or outside wall opening.
centerline
terminal
box
7a
~TO wire through top,
mark a line
7-l /2” from the riaht of the centerline on
the underside ofThe cabinet. Mark the
point on this line that is l-3/8” from the back
wall. Drill a l-l /4” diameter hole through
cabinet at this point.
keyhole slot
Check that screw is in
narrow neck of slot.
front of hood
12
m
screw
H Start screws in the center of
the narrow neck of each of the four
keyhole mounting screw slots marked on
the cabinet bottom.
H Remove terminal box cover
I
I
0
di
J
.___.-,-.-.
“r
5
I,
1-W
! 7-lfl’
&I-5/8”
I
00
floor) i
I
4
\I,
I
on
13
W Lift range hood into final
range hood.
position, feeding electrical wire through
wiring opening. Tighten mounting screws to
cabinet, making sure mounting screws are
in narrow neck of slots.
Excessive Weight Hazard
Use two or more people to move and
install range hood.
Failure to follow this instruction can
result in back or other injury.
+ I
centerline
To wire through rear,
mark a line 7-l /2” from
the right of the centerline on the wall. Mark
the point on this line that is &l-5/8” from the
floor (or l-3/8” from underside of cabinet).
Drill a l-l /4” diameter hole through wall at
this point.
front oi hood
keyhole slot
Sa
W Lift range hood into final
Electrical Shock Hazard
Disconnect power before making
electrical connections.
Connect ground wire to green ground
screw in terminal box.
Failure to do so can result in death or
electrical shock.
8a
n
Run wirina throuah wall or
cabinets according to’ the N$ional
Electrical Code and local codes and
ordinances.
Do not turn on power until
installation is complete. Use caulking to
seal ceiling or outside wall opening.
position and center. Mark on underside of
cabinet the location for the four keyhole
mounting slots. Set range hood aside on a
protected surface.
keyhole slot
front of hood
Check that screw is in
narrow neck of slot.
9a
m
screw
H Start screws in the center of the
narrow neck of each of the four keyhole
mounting screw slots marked on the
cabinet bottom.
1
I Connect the white and black
wires of the power supply cable to the
white and black leads in the range hood
with twist-on connectors.
Connect the power supply ground wire to
the green ground screw inside the range
hood terminal box.
Use caulking to seal wire opening.
Replace terminal box cover.
IOa
W Lift range hood into final
centerline
6a
n
Determine and clearly mark a
position, feeding electric%1 wire through
wiring opening. Tighten mounting screws to
cabinet, making sure mounting screws are
in narrow neck of slots.
vertical centerline in the cabinet opening.
Panel D