ELECTRICAL COMPONENTS INSTALLATION INSTRUCTIONS
A. HI-LIMIT THERMOSTAT
1. Install THERMOWELL in lower threaded hole
in frypot. Use hi-temperature pipe thread
compound.
2. Insert HI-LIMIT THERMOSTAT thermobulb
into THERMOWELL. DO NOTuse any type
of pipe thread compound or tape. Thread the
compression fitting into THERMOWELL and
tighten finger-tight only.
NOTE: The thermobulb sits in the thermowell,
and not directly in the hot oil. Thus it is not
necessary to over-tighten the compression fitting.
Wrench tightening this fitting will make it impossible
to remove should service be required at a later date.
3. Attach body of HI-LIMIT THERMOSTAT to the left mounting
bracket below the control panel and connect wiring.
B. TEMPERATURE CONTROL THERMOCOUPLE
1. Install THERMOCOUPLE in upper threaded hole in frypot. Use hi-temperature pipe thread
compound.
2. Tighten using a slotted 9/16" deepwell socket or offset flare nut wrench, taking care to not
damage the thermocouple leads.
3. Connect thermocouple leads to controller terminals 2 (white or +) and 3 (red or -).
9/16“SLOTTED
DEEPWELL SOCKET
19