— 7 —
LEVELING
Casters for this oven are of the non-adjustable type. Therefore, the floor must be level. If floor surface
is not level, the oven will experience cooking problems.
GAS CONNECTIONS
Gas supply connections and any pipe joint compound must be resistant to the action of propane gases.
Location of the
3
⁄4" gas inlet is at the back of the oven on the lower right side.
Codes require that a gas shutoff valve (available from Vulcan-Hart) must be installed in the gas line
ahead of the oven.
Connect gas supply. Make sure the pipes are clean and free of obstructions.
The ovens are equipped with fixed burner orifices which coincide with installation elevation.
Natural gas and propane gas are preset at the factory for proper operation. Store line pressures are
preset for 7" W.C. (Water Column) (1.75 kPa) for natural gas and 11" W.C. (2.75 kPa) for propane gas.
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
TESTING THE GAS SUPPLY SYSTEM
When gas supply pressure exceeds
1
/2 psig (3.45 kPa), the oven and its individual shutoff valve must
be disconnected from the gas supply piping system. When gas supply pressure is
1
/2 psig (3.45 kPa)
or less, the oven should be isolated from the gas supply system by closing its individual manual shutoff
valve.
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL
ELECTRICAL CODES.
WARNING: APPLIANCES EQUIPPED WITH A FLEXIBLE ELECTRIC SUPPLY CORD ARE
PROVIDED
WITH A THREE-PRONG GROUNDING PLUG. IT IS IMPERATIVE THAT THIS PLUG BE
CONNECTED INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. IF THE
RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT
REMOVE THE GROUNDING PRONG FROM THIS PLUG.
The oven is equipped with a power supply cord for service at 120 volts and 20 amps. A 20 amp
receptacle and service is required for proper operation of the oven.