![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/b8/3b8375ff-97fe-4bd9-81e4-81fbb991d4aa/3b8375ff-97fe-4bd9-81e4-81fbb991d4aa-bga.png)
— 10 —
PL-51219
CONNECT GAS LINE
STRAIN
RELIEF HERE
In Canada:
1. Local codes.
2. CAN/CGA-B149.1 Natural Gas Installation Code (latest edition).
3. CAN/CGA-B149.2 Propane Installation Code (latest edition), available from The Canadian Gas
Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.
4. Canadian Electrical Code, CSA C22.2 No. 3 (latest edition). Copies may be obtained from The
Canadian Standard Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.
RANGES MOUNTED ON CASTERS
When ranges are mounted on casters, you must use a connector (available from Vulcan-Hart) that
complies with the Standard for Connectors of Movable Gas Appliances, ANSI-Z21.69 (latest edition),
and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices
Complying With Gas Fuel, ANSI-Z21.41 (latest edition) or CAN 1-6.9 (latest edition).
Provide a gas line strain relief to limit movement of the range(s) without depending on the connector
and/or any quick-disconnect device or its associated piping to limit movement of the range(s). Attach
the strain relief to the rear of the range (Fig. 1).
Should it be necessary to disconnect the strain relief, turn off the gas supply before disconnection.
Reconnect the strain relief before turning the gas supply on and returning the range(s) to their
installation position.
Fig. 1
LEVELING
Curb Installation
Ranges must overhang curb 3" (8 cm) in front. To level each range, remove oven bottom. Adjust four
corner leveling bolts as required to level the appliance on all sides.