— 8 —
PL-52620
Optional Electrical Connection
Pressure Regulator
Gas Valve
Install the gas pressure regulator. Natural gas pressure regulators are preset for 3.7" W.C. (Water
Column); propane gas pressure regulators are preset for 10" W.C. When connecting fittings to the rear
inlet pipe projecting through the body back of the oven, hold back on this pipe with a wrench to eliminate
any excess strain on the internal oven piping.
Because this oven is equipped with fixed orifices on the pilots and the two main burners, the pressure
regulator must be installed to ensure the proper input. If the pressure regulator is installed in other than
a horizontal position, a field adjustment of the pressure regulator will be required.
The drop in gas pressure with all appliances in operation should not exceed
1
/2" water column prior to
the regulator. Be sure the meter has ample capacity for all appliances on the line when all are in
operation.
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
Fig. 4