Battery recharge rate 2-4 hours to 90%
Replacement
Battery Cartridge
RBC54
VOLTAGE REGULATION
Voltage regulation
description
Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without
using battery power, during brownouts to 79V and overvoltages to 147V
Overvoltage
correction
Input voltages between 128 and 147VAC are reduced by 12%
Direct pass through Input voltages between 105 and 127VAC are passed on to connected equipment unchanged
Brownout correction Input voltages between 95 and 104VAC are boosted by 12%
Severe brownout
correction
Input voltages between 79 and 94VAC are boosted by 24%
LEDS ALARMS & SWITCHES
Front panel LEDs Includes 5 front panel LEDs to indicate BATTERY CHARGE LEVEL, AC LINE POWER STATUS, VOLTAGE
REGULATION STATUS, UPS LOAD LEVEL and BATTERY LOW / REPLACE information
Alarms Audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous short beeps)
and low battery (continuous tone)
Switches Yes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
SURGE / NOISE SUPPRESSION
AC surge
suppression
480 joules
AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Shipping weight
(lbs)
58.8
Shipping weight (kg) 26.7
Shipping
Dimensions
(HWD/in)
16 x 14.75 x 19.75
Shipping
Dimensions
(HWD/cm)
40.6 x 37.5 x 50.2
Unit weight (lbs) 52.4
Unit weight (kg) 23.8
Unit Dimensions
(HWD/in)
14.25 x 9.25 x 12.00
Unit Dimensions
(HWD/cm)
36.2 x 23.5 x 29.8
Material of
construction
Polycarbonate
Form factors
supported
Tower
Cooling method Built-in cooling fan
Battery Access Battery access door allows user battery replacement
ENVIRONMENTAL
Relative Humidity 0 to 95%, non-condensing
Storage Temperature +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius