![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/62/3626966e-3e06-40dc-8f60-8fe4ec153271/3626966e-3e06-40dc-8f60-8fe4ec153271-bg50.png)
Chapter 2 Troubleshooting Procedures
2.16 Camera Troubleshooting
To check if the computer’s Camera is malfunctioning or not, follow the troubleshooting
procedure below as instructed.
Procedure 1: Camera Execution Check
Procedure 2: Connect Check and Replacement Check
Procedure 1 Camera Execution Check
Open photo/video tool to look if there is an image. If not, go to Procedure 2.
Procedure 2 Connect Check and Replacement Check
The CCD cable is connected to system board integrated with LCD cable. If camera
malfunctions, its connection may be defective or LCD/CCD cable and system board may be
faulty.
Check 1 Make sure the other side of CCD cable is correctly and firmly inserted to the
CN3/CN8 in MB. If the problem still occurs, perform Check 2.
Check 2 CCD cable may be faulty. Replace it with a new one. If the problem still occurs,
perform Check 3.
Check 3 Camera may be faulty. Replace it with a new one following the instruction in
Chapter 4.
Check 4 System board may be faulty. Replace it with a new one following the instruction in
Chapter 4.
Satellite L600D/L640D/L645D, Satellite Pro L600D/Pro L640D/Pro L645D Maintenance Manual (960-Q08)