13
Hardware Installation
Bottom of the
Camera
First, use the supplied torx wrench to detach the dome cover from the camera
base. Then, follow the steps below to install the camera; either to a ceiling or to a
wall.
Connect the appropriate power cables and external devices such as sensors and
alarms, to the general I/O terminal block.
Cabling Assembly
For Ethernet
Cable
For Power &
IO Cables
Top View
Power and IO cables pass through a
waterproof connector. The Ethernet cable
should be routed through the supplied
gasket. All cables are user-supplied.
Operating environment:
PoE : –30 °C ~ +50 °C {–22 °F ~ 122 °F}
24V AC, 12V DC : -25°C ~ +50 °C {–13 °F ~
122 °F} *1
The operating temperature range changes
with kinds of power supply which uses this
camera.
*
1 When the camera is installed and
operated in low temperatures below –10 °C
{14 °F}, normal images may not be obtained
immediately after startup. In such a case,
wait until the camera warms up (taking
more than 1 hour) and start adjustment after
turning on the power again.
NOTE
Record the MAC address under the
camera base before installing the
camera.