A SERVICE OF

logo

UNITEC
Motor
Complete
1
<
ITEM NO PART
NO
DESCRIPTION
1 761-023 Screw
2 761-027 Rear Cover
3
611-405 Snap Ring
4
702-040 Outer Fan
5
700-681 Screw
6
761-028 Rear Motor Housing
7
702-047 Wave Washer
8
761-302 Armature 120V
For 230 Volt Units:
ITEM NO PART NO
DESCRIPTION
8
761-231
Armature 230V
5
<
QTY
2
1
1
1
4
1
1
1
QTY
1
18
Figure 4
Armature
Replacement
WARNING: Before proceeding, follow
the
Pressure
Relief Procedure outlined on page 5. Additionally,
follow all
other warnings to reduce the risk of an
injection injury, injury from moving parts or electric
shock. Always unplug the sprayer before servicing!
1. Remove Rear Cover (#2) by taking out
screws
(#1
).
2. Remove Snap Ring (#3).
3. Remove Fan (#4).
4. Remove Rear Motor Housing (#6) by removing screws
(#5).
NOTE: Make sure to remove Wave
Washer
(#7)
which should be on the End Bearing
of
the Armature.
5. Remove Motor Brushes.
Follow Brush replacement
procedure located on page 20.
6. Remove Armature by gently rocking
and
pulling Fan
from rear of pump.
7.
Inspect Armature. If damaged, replace.
8.
To replace Armature, reverse steps 1 through 6 here.
(
\