DV425TR DIRECT VENT ROOM HEATER
02/01 Page 13 250-5533
LP CONVERSION INSTRUCTIONS
Part #844-9010
KIT CONTENTS: Replacement orice (ts top
vent models only); replacement pilot injector.
TOOLS REQUIRED: Power drill (a 90° handle is
helpful); #2 Phillips bit; 5/32" Allen wrench; 5/8" open
end wrench.
1. Remove front (if installed), glass, and logs (if
installed.)
2. Remove log/burner pan: First remove screws
then lift the front of pan vertically and slide pan to
one side and pull out of rebox. Fig. 1
3. Remove burner plate.
4. Pull off pilot hood and set aside. Fig. 2
5. Use a 5/32" Allen wrench to remove the pilot
injector. Fig. 3
5. Replace pilot injector with the one supplied in the
conversion kit (#35 for Propane, #62 for Natural
Gas).
NOTE: The injector is ONLY replaced if you are con-
verting to another gas. It is not replaced for a
change from top to rear vent.
6. Replace pilot hood, snapping into position.
7. Remove main burner orice using a 5/8" wrench.
8. Replace orice with the proper size as indicated
below for your gas type and venting: Fig. 4
PROPANE NATURAL GAS
Top Vent: .063 (52 DMS) .106 (36 DMS)
Rear Vent: .059 (53 DMS) .096 (41 DMS)
IMPORTANT NOTE! The orice supplied with this
conversion kit is for TOP VENT MODELS ONLY. If
your stove was tted with the rear vent kit, the
correct conversion orice was supplied WITH THE
REAR VENT KIT.
See next page for Valve Regulator Replacement:
FIG. 1
MILLIVOT GENERATOR
PILOT HOOD
THERMOCOUPLE
Pilot Hood
FIG. 2
FIG. 3
FIG. 4