© 2004 SPX Corporation
1212
1212
12
Operating Procedures
Manual/Top-Off Mode
continued
Adjust the ATF Level
1. In step 2 under “Power Up,” the ATF level
was determined noting whether ATF needed
to be added, subtracted, or it was satisfactory.
a.
If the level is too low, select
To Trans
LED.
(1) Press Enter.
(2) Press the arrow key to select how
much fluid to add (each press indicates one-
tenth of a quart).
(3) Pause after the correct volume is
selected. The ENTER key lights and flashes.
(4) Press ENTER to start the service.
b. If the level is too high, select
From
Trans
LED.
(1) Press Enter.
(2) Press the arrow key to select how
much fluid to take out (each press indicates
one-tenth of a quart).
(3) Pause after the correct volume is
selected. The ENTER key lights and flashes.
(4) Press ENTER again to start the
service.
c. If the transmission fluid pan needs to
be removed, press SELECT until
Drn Pan
appears on the display.
(1) Pause until ENTER LED lights (about
one second).
(2) Press ENTER to confirm the function.
(3) Press ENTER again to start draining
the pan. The unit will stop when pan is empty.
Refill Transmission Fluid Pan
To refill the transmission fluid pan,
1. Press SELECT until the
To Trans
LED is lit.
2. Press ENTER. The amount removed will
display on the
Replaced Fluid Out
display.
3. Adjust the
New Fluid In
display to match the
Replaced Fluid Out
display.
4. Press ENTER.
Drain Waste Tank
Transfer used ATF from the internal waste tank
to an external waste ATF reservoir.
Power Up
1. Connect the power cord to a 12V DC
battery: red to the positive post and black to
the negative post.
2. Ensure the unit’s hoses are disconnected
from the vehicle.
3. Turn the unit on. The
Reversed Polarity
LED
lights if the power is connected incorrectly.
The unit self-tests: The buzzer sounds, all
LEDS and displays light and flash, the
flexible nylon hose evacuates ATF, and the
software version displays.
4. Disconnect the red hose from the wand
assembly. Connect the drain waste adapter
(#546763) to the red hose, and place into an
external waste ATF reservoir.
Start Service
1. Press the SELECT button until only the
Drain Waste Tank
LED is lit and flashing.
2. Pause until the ENTER LED lights and
flashes (about one second).
3. Press ENTER to confirm the selection. The
display reads DRN (XXX), which is the
amount left to be drained.
When the waste tank is drained, the display
reads SR FIN, indicating service is finished.