4 - 8
4. SIGNALS AND WIRING
(7) MR-J3-11KT to MR-J3-22KT
NFB MC
L
1
L2
L3
P
C
U
V
W
TE
PE
L
11
L21
U
V
W
M
CN2
(Note 5)
P
1
(Note 1)
(Note 2)
RA2
24VDC
power supply
OHS2OHS1
BU
BV
BW
(Note 6)
MC
SK
MC
ON
OFF
Trouble
RA1
3-phase
380 to
480VAC
Servo amplifier
Dynamic
break
(Option)
Servo motor
Cooling fan
Servo motor
thermal relay
Servo motor
thermal relay
RA2
Motor
Forced
stop
(Note 3)
Encoder cable
Encoder
Regenerative
resistor
RA
DOCOM
24VDC
EMG
CN6 CN6
DOCOM
DICOM
ALM
Trouble
(Note 4)
Forced stop
(Note 4)
RA
NFB
Note 1. Always connect P1 and P2. (Factory-wired.) When using the power factor improving DC reactor, refer to section 14.11.
2. Connect the regenerative resistor. When using the regenerative option, refer to section 14.2.
3. For the encoder cable, use of the option cable is recommended. Refer to section 14.1 for selection of the cable.
4. For the sink I/O interface. For the source I/O interface, refer to section 4.8.3.
5. Refer to section 4.10.
6. Cooling fan power supply of the HA-LP11K2 servo motor is 1-phase. Power supply specification of the cooling fan is different
from that of the servo amplifier. Therefore, separate power supply is required.