A SERVICE OF

logo

2
PUMP RECOMMENDATION FOR
COPPER-FIN II 0991-1441 POOL HEATER
Pump Specifications
Part No. HorsePower Flanges Valute Material Flange Material Vendor Vendor Product Series Orientation
ARM3024PABTE 1/2 2-1/2" Brass Brass Armstrong 2B1050 Vertical
Installation Specifications
Recommended for Based on
Pump Model Numbers Maximum GPM Installation Type
Copper-Fin II Pool Htr, CP(N,L) 0991-1441 90 GPM Single Pool Heater piped Primary/Secondary to Pool Loop
ARM3024PABTE Based on Based on
Minimum Pipe Diameter Connecting piping
2-1/2" Maximum 45 feet straight pipe with 6-Elbows, 2-Unions and 2-Ball Valves
IMPORTANT: Read the Copper-fin II 500-2070 Pool Installation and Operation Manual. If the planned
system exceeds the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps
and pump curves.
PUMP
Recommendation
PUMP-Rec-08 Rev C
OIL PORT
A
C
B D
11-1/2”
19-1/2”
16”