Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
OUTPUT RECTIFICATION,
CONTROL BOARD AND FEEDBACK
The AC output from the main transformer secondary is
rectified and controlled through the SCR bridge.
Output current is sensed at the shunt as a low voltage
signal and fed back to the control board. The control
board senses the status and settings of the various
operator controls such as the mode switch, the output
control, the remote control receptacle, the downslope
control, the balance control and the postflow control.
Circuitry on the control board evaluates these com-
mands, compares them to the feedback information
received from the shunt and sends the appropriate gate
firing signals to the output SCR bridge. The control
board regulates the firings of the output SCRs, which
control the output of the machine. See
SCR
Operation.
The control board also monitors the ther-
mostats and controls the gas solenoid, the thermal light
and the cooling fan.
THEORY OF OPERATION
E-3 E-3
SQUARE WAVE TIG 275
FIGURE E.3 – OUTPUT RECTIFICATION, CONTROL BOARD AND FEEDBACK